Connecting your building’s main water line to the city’s water main: what is involved, who decides what, and how Flowlex coordinates the work with your utility.
The water service is the pipe that brings drinking water from the utility’s water main in the street to your building. Along the way it passes the utility’s connection and meter, then continues on your side of the meter to the building.
New buildings need a new service. Older services leak, corrode or are too small and get replaced. In every case, the utility that serves the address decides how the connection to its system is made.
A new or replaced water service touches your property, the street and the utility’s system. Flowlex coordinates with the utility, handles the paperwork and keeps you informed from the first call to the final connection.
Permit applications, submittals and inspections are prepared and coordinated for you, so nothing stalls between offices.
One team, one schedule and one point of contact from the site visit to the final inspection.
Send your plans, survey or city comments one time. We review them and come back with the next steps.
We follow up by phone or email and explain what your city or county requires, in plain English.
The connection at the main and the meter belong to the utility’s system. The utility sets the rules for how they are requested and installed.
The line from the meter to the building is the property owner’s. Confirm with your utility exactly where that line is drawn.
Work on the line is done under the permits the city and the utility require, and the required inspections are scheduled with them.
What the utilities and agencies publish, with the official source for each item.
The utility that serves your address sets the rules for the connection. Confirm the current requirements with your utility before any work begins.
The City of Hollywood requires a plumbing permit for a new water meter, applied for by the contractor (or the owner where the Florida Building Code allows), with a sketch showing the location and size of the backflow preventer, water meter and water service line. [1]
In Hollywood, the contractor installs the backflow preventer and plumbing downstream of the meter, and after the new-meter request is paid the City's Utility Billing Division sends a service order to Underground Utilities, which installs the meter; a final plumbing inspection follows. [1]
The City of Hollywood Building Division requires a plumbing permit to install or replace any backflow device, residential or commercial, with backflow specifications and a field test report submitted. [2]
The City of Hollywood's backflow program (mandated by Florida DEP) applies to homes with a dedicated irrigation connection, a dedicated fire service connection, or a private well or other auxiliary water source, and those devices must be re-certified every year. [3]
The City of Pembroke Pines requires a dual check valve (DuC) backflow device on residential service connections; the City owns and installs it when it sets the meter, under City Code Chapter 50.40 and Florida rule 62-555.360. [4]
The City of Pembroke Pines engineering standards say water meters and meter boxes two inches or smaller are supplied and installed by the City, at the owner's cost. [5]
The City of Miramar installs all water meters itself; meters under two inches go underground in an approved meter box, and meters may not be placed under sidewalks or pavement. [6]
The City of Miramar requires backflow prevention assemblies to sit directly after the water meter on the property owner's side, above ground, and makes the developer or owner responsible for installing and maintaining them. [6]
The City of Fort Lauderdale requires a Utility Service Application (filed through LauderBuild) for domestic or irrigation water services 4 inches and larger and fire services 2 inches and larger; smaller connections go through the plumbing permit forms. [7]
The City of Fort Lauderdale requires domestic backflow assemblies to be installed by a licensed plumbing contractor under a plumbing permit, and requires every irrigation meter to have a PVB or RP backflow device (City Code Sections 28-152 to 28-157, codified April 21, 2015). [8]
Miami-Dade WASD requires an application for new service to install a water service line from an existing main for the first time, or to move a service more than five feet; WASD performs the service installation, and the request needs a signed and sealed survey or site plan. [9]
Miami-Dade WASD sets the meter only after the property's private plumbing has been connected to the new service installation. [9]
Miami-Dade WASD's Cross-Connection Control and Backflow Prevention Program requires certain backflow assemblies (for example on irrigation, fire, commercial and some multi-family properties) to be tested at installation and every year by a certified tester. [10]
The City of Hallandale Beach's Water Distribution Services section maintains the City water system, which includes the water mains, service lines, valves and water meters. [11]
The City of Aventura lists Miami-Dade WASD and the North Miami Beach Public Services Department among the outside agencies that may need to review plans before the City issues a permit. [12]
Florida DEP requires every community water system to run a cross-connection control program that finds and controls cross-connections and prevents backflow (Rule 62-555.360, F.A.C.). [13]
Under Florida DEP rules, when a utility finds a prohibited cross-connection it must either have an approved backflow device installed or shut off service until the hazard is removed. [13]
Florida DEP rules strictly prohibit cross-connections between reclaimed-water lines and drinking-water systems (Rule 62-610.469(7), F.A.C.). [14]
Florida Statutes section 403.855 lets the Florida DEP set up programs to prevent contamination of drinking water supplies. [15]
Anything not shown here: confirm with your utility.
Two ways to handle the permit. We can handle the permit process for you, or, if you prefer to do it yourself, here are the official links. Forms are always filed with the city or county, never through Flowlex.
The utility that serves your address. Its rules cover the connection to the main and the meter; confirm the current requirements with your utility.
In general, the property owner. Confirm with your utility exactly where its responsibility ends at your property.
Work on a water service is done under the permits the city and the utility require. Confirm the current requirements with your utility and building department.
It depends on the length of the line, the site and what the utility requires. You get a written price after we review your plans or visit the site. Want a price? Contact us: call (754) 444-0650 or upload your plans and request pricing.
Every fact on this page comes from these official government pages. Rules change, so the agency’s own page is always the final word.
Want a price? Contact us. Upload your plans or describe the project; we review it and follow up by phone or email.